Material |
Housing |
PA66 |
Contacts |
Copper Alloy, Au Plating |
Hex Nut / Gland Nut / Clamp |
PA66 |
Gasket / O-Ring |
Silicone |
Gland |
NBR |
Machine Screw |
S15C |
Terminal |
Beryllium Copper, Sn Plating |
Technical Data |
Visual and Dimensional Inspection |
Must meet or exceed the requirements specified by the most current version of the Power Specification. |
Insulation Resistance |
DC 500V±10%, test for 1 minute and the insulation resistance should be more than100MΩ |
Dielectric Withstanding Voltage |
Power Pin: 2500 V AC contact-to-contact, for 1min. |
Contact Resistance |
10mΩ at 10mA Max. |
Durability |
200 cycles insertion/extraction cycles at a maximum rate of 500cycles per hour. |
Cable Pull-Out |
After the application of a steady state axial load of 45 N for one minute. |
Machine Screw Force |
Insert stripped wire into screw-in pin, tighten. [2.0 Nm]min. |
Physical Shock |
No discontinuities of 1 μs or longer duration when mated Power connectors are subjected to 11 ms duration 30 Gs half-sine shock pulses. Three shocks in each direction applied along three mutually perpendicular planes for a total of 18 shocks. |
Random Vibration |
The electrical load conditions shall be 100mA maximum for all contacts. Frequency: 50 to 2000 Hz PDS: 0.04 g² /Hz. Duration: 1 Hour/Axis, 3 Axes Total. g’s: 7.56 g rms |
Thermal Shock |
5 cycles at -40°C / +105°C, after the test, the function and appearance can't be impacted. |
Humidity Life |
96 hours minimum (seven step cycles). |
Salt Spray |
The test liquid (Nacl) thickness is 5%, Compressing the air pressure is 0.083Mpa, Spraying amount is 1~2 ml/80cm/h, Temperature of the pressure barrel is 43°C, LAB temperature is 35°C, relative humidity of LAB is 95%~98%, test time is 48 hours, after the test, check if there is rusty and oxidized phenomenon |
Waterproof Test |
Submersion in water 1 meter for 30 minutes. |
Temperature Life |
85°C for 48Hours Method A, Mated |
Cycling Humidity |
4 cycles at 25°C / +85°C 95% RH (1 cycles/day) |
UV Exposure |
24 H equal 1 year: 8 h UV at 70 (±3) °C Black Panel Temperature 4 h Condensation at 50 (±3) °C Black Panel Temperature |